Product Name: UV Microporous Membrane System for Non Sterilizing Drugs Preparation
Application Range:
Solvent or experimental water for pharmaceutical preparations .
A Solvent or diluent for oral and external preparation.
Cleaning Water for Wears used for Non Sterilizing Preparation.
Extraction Solvent for non sterilizing drugs .
A solvent and diluent for preparation of a injection.
Cleaning Water for vessel used for injection .
Solvent for eye drops.
Solvent for sterilized powder used for injection or diluent for injection
Typical Preparation Process:
The raw water ---The raw water pump ---Multi-media Filter---Activated Carbon Filter---Automatical softener device---Safe Filter---the first stage HP Pump---the first RO Device---The middle water tank---the second HP Pump---the second RO Device ---Pure Water Tank-- Water Pump---UV --Microporous Membrane Filter---the used water point (New Technology)
Technical Parameter:
Output Water Capacity | 0.5m3/h--50m3/h |
TOC | <100PPB |
Conductivity | <0.5μs/cm |
Microorganism | <100 CFU/ml |
Endotoxin | <0.25EU/ml |
Nitrate | <0.06PPM |
Heavy metal | <0.1 PPM |
FAQ:
1.Question: How to maintain the water treatment equipment ?
Answer : Purified Water Equipment can be remotely controlled , In case there is fault of software .
2.Question:How to treat hardware problem during the guarantee period ?
Answer : Directly contact with us , CHONGYANG Water is responsible for changing parts with free. The customer bear freight cost .
3.Question : How to deal with small problem during working day ?
Answer : By wechat ,whatapp on-line in time.